Your browser doesn't support javascript.
loading
Treatm ent of four different fixation of metacarpal and phalangeal fractures / 中国医师杂志
Journal of Chinese Physician ; (12): 29-32, 2010.
Article em Zh | WPRIM | ID: wpr-451560
Biblioteca responsável: WPRO
ABSTRACT
Objective Analysis of applies the Cleveland needle , Miniature steel plate , Outside the steady rest in treatment palm phalanx bone fracture .Methods Three hundred and twenty -six example 394 palms, phalanx bone fractures .A group of 126 example 157 use in the Cleveland needle fixed;B group of 81 example 99 use in the AO steel plate fixed;Outside C group of 93 example 108 use the steady rest to be fixed;D group of 26 example 30use may absorb in the nail fixed . Surgery time,technique the joint func-tion restores the situation , the bone fracture cicatrization time and the complication occurrence were ana-lyzed.Results TAFS grades:A group was 77.8%;B group was 96.3%;C group was 96.7%.D group was 96.2%( P<0.05 ) .Conclusion Because of different to loss degree palm , we should select and use the different inner or outside fixture respectively .
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Journal of Chinese Physician Ano de publicação: 2010 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Journal of Chinese Physician Ano de publicação: 2010 Tipo de documento: Article