Research on applied analysis on 64 row spiral CT post-processing technique in the occult fracture of rib / 中国医学装备
China Medical Equipment
; (12): 105-107, 2014.
Article
em Zh
| WPRIM
| ID: wpr-456644
Biblioteca responsável:
WPRO
ABSTRACT
Objective:To explore the clinical application value of multi-slice spiral CT in the diagnosis.Methods: Twenty nine patients with clinically suspected rib fractures and X-ray showed no 64 row helical CT scanning in patients with chest trauma fractures after reconstruction, multiplanar reconstruction and VR imaging.Results: Twenty nine patients with occult fracture of rib on the MPR, VR imaging were rib image good, 28 cases were single, multiple rib fractures in 1 cases, the total of 4 cases with rib fracture, incomplete fracture in 25 cases.Conclusion: The 64 row helical CT for occult rib fracture detection rates, diagnostic accordance rate was superior to X-ray plain film, various post-processing techniques applied to timely, accurate, intuitive display rib fracture location, shape, extent of chest trauma, occult rib fracture first choice inspection method.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
China Medical Equipment
Ano de publicação:
2014
Tipo de documento:
Article