ABSTRACT
Objective To establish the quality control method for Antenoron filiforme. Methods Antenoron filiforme was identified by TLC,and the content of gallic acid was determined by HPLC. The chromatographic conditions were as followsAichrom Reliasil C18 column (4. 6 mm×250 mm,5 μm) was used with mobile phase consisted of acetonitrle-0. 1% phosphoric acid(4∶96),the flow rate was 1. 0 mL·min-1 ,and the detection wavelength was 270 nm. Results TLC identification for An-tenoron filiforme was highly specific. Gallic acid content had a good linearity in the range of 0. 08-0. 56μg (r=1. 000 0). The av-erage recovery was 101. 12% and RSD was 2. 20% (n=6). Conclusion The method is simple, feasible,and reproducible, and can be used for the quality control of Antenoron filiforme.