Surface location of right atrial central point by echocardiography / 中华超声影像学杂志
Chinese Journal of Ultrasonography
;
(12): 291-293, 2015.
Artigo
em Chinês
| WPRIM
| ID: wpr-463518
ABSTRACT
Objective To propose an accurate method of noninvasive determination of central venous pressure(CVP ) by locating the central point of right atrium (RA ) using echocardiography .Methods Through the 3D reconstruction ,the accurate positions of RA of 30 patients who had been examined by multislice 3‐dimensional computed tomography for chest imaging were recorded .Based on solid geometric principles ,the central point in RA was located by echocardiography and then compared with CT‐location point .The accuracy and feasibility were assessed by absolute distance (Da) ,vertical distance (Dv) and the whole time of location (T) between the two points .Results Mean Da ,Dv and T of the whole subjects were 07.6cm(95% CI06.2to08.1cm),01.6cm(95% CI-00.2to03.4cm),and438.0s(95% CI400.1to 47 4.0 s) ,respectively .Conclusions The echocardiographic method on the basis of solid geometry proposed in this study could be used to locate the central point in RA accurately and simply .Thus it would be helpful to improve the accuracy of noninvasive determination of central venous pressure .
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Idioma:
Chinês
Revista:
Chinese Journal of Ultrasonography
Ano de publicação:
2015
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS