PRGD composite nerve conduit in repair of human peripheral nerve defect in upper extremity / 中华显微外科杂志
Chinese Journal of Microsurgery
;
(6): 130-133, 2015.
Artigo
em Chinês
| WPRIM
| ID: wpr-469313
ABSTRACT
Objective To explore the clinical efficacy of PRGD composite nerve conduit in the treatment of human large-diameter,critical peripheral nerve defect in upper extremity.Methods From December,2011 to August,2014,19 patients with large-diameter,critical peripheral nerve defect in upper extremity were treated with PRGD composite nerve conduit.The patients were followeded-up periodically.The sensory and motor function recovery,high frequency ultrasound,and EMG were employed to assess the efficacy.Results The patients were followed up for an average time of 12-32 months(mean 21.75 ± 6.86 months),sensory and motor function recovered excellent in 7 patients,satisfactory in 7 patients,tolerable in 3 patients and no improvement in 2 patients were obtained according to the peripheral nerve function assessment standard built by British medical research council,the rate excellent and satisfactory results was 73.7%.Conclusion It is clinically promising to use PRGD composite nerve conduit to repair large-diameter,critical peripheral nerve defect in upper extremity,thus laying a foundation for its further application in clinical practice.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Idioma:
Chinês
Revista:
Chinese Journal of Microsurgery
Ano de publicação:
2015
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS