Methods for the prevention of internal jugular vein malposition of peripherally inserted central catheter in patient with limited neck motion / 中华临床营养杂志
Chinese Journal of Clinical Nutrition
;
(6): 317-320, 2014.
Artigo
em Chinês
| WPRIM
| ID: wpr-470453
ABSTRACT
Objective To evaluate the methods for the prevention of internal jugular vein malposition of peripherally inserted central catheter (PICC) in patient with limited neck motion.Methods 210 patients who underwent PICC placement using ultrasound-guided modified Seldinger technique were divided into observation group (n =106) and control group (n =104) with a random number table.Ultrasound probe compression on the internal jugular vein was used in the observation group,while finger compression was used in the control group.The 2 groups were compared in terms of incidence of internal jugular vein malposition,accuracy of PICC tip position in X-ray,and incidence of complications.Results Incidence of PICC malposition was significantly lower in the observation group than the control group [3 (2.8%) vs.36 (34.6%),P =0.000].The accuracy of PICC tip position in both groups was 100%.No complication was observed in the observation group,while the rate of complication in the control group was 4.8%,with a statistically significant difference (P =0.022).Conclusion The ultrasound probe compression method can significantly lower the incidence of internal jugular vein malposition of PICC and is safer than the finger compression method.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Idioma:
Chinês
Revista:
Chinese Journal of Clinical Nutrition
Ano de publicação:
2014
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS