Analysis of the Mammotome system minimally invasive excision of breast lesions in 1081 patients / 中国介入影像与治疗学
Chinese Journal of Interventional Imaging and Therapy ; (12): 537-540, 2009.
Artigo em Chinês | WPRIM | ID: wpr-471370
ABSTRACT
Objective To evaluate the clinical application of ultrasound-guided Mammotome system in the treatment of breast lesions.Methods A total of 1081 patients with 1913 breast lesions received Mammotome minimally invasive excision,and the efficacy of treatment and follow-up results were retrospectively analyzed.Results All 1913 lesions in 1081 patients were treated with the Mammotome system.The duration of operation was 4 minutes,and the average excision times was 15 for every lesion,1894 lesions (99.01%) in 1063 patients were benign breast masses,19 lesions (0.99%) in 18 patients were breast carcinoma.Complication occurred in 39 lesions (2.04%).Conclusion Ultrasound-guided Mammotome system is one of the effective ways in the clinical diagnosis and treatment of breast lesions.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Interventional Imaging and Therapy Ano de publicação: 2009 Tipo de documento: Artigo