Your browser doesn't support javascript.
loading
Estimation of Body Fluid Volume by Bioimpedance Spectroscopy in Patients with Hyponatremia
Yonsei Medical Journal ; : 482-486, 2014.
Artigo em Inglês | WPRIM | ID: wpr-47155
ABSTRACT

PURPOSE:

Estimation of body fluid volume in hyponatremia is useful for diagnosis and therapeutic decision-making. Physical examination has been generally used to estimate body fluid volume, but it depends on the physician's abilities. Bioimpedance spectroscopy has been suggested to be a reliable method for the estimation of body fluid volume. Therefore, this study investigated whether bioimpedance spectroscopy could replace physical examination in hyponatremia. MATERIALS AND

METHODS:

The study included 30 patients with hyponatremia. At the time of the initial visit, body fluid volume was estimated simultaneously by both physical examination and bioimpedance spectroscopy. Estimation of body fluid status by clinical diagnosis was performed as well, which determined body fluid status corresponds with the most likely cause of hyponatremia (clinical body fluid estimation).

RESULTS:

The results of body fluid volume estimated by physical examination, bioimpedance spectroscopy, and clinical body fluid estimation showed that 9, 10, and 9 patients, respectively, were hypervolemic; 13, 15 and 16 patients, respectively, were euvolemic; and 8, 5, and 5 patients, respectively, were hypovolemic. Cohen's kappa analysis showed a significant agreement between physical examination and bioimpedance spectroscopy (kappa coefficient, 0.632, p<0.001). In addition, bioimpedance spectroscopy showed a higher level of agreement with clinical body fluid estimation than physical examination (kappa coefficient, 0.602 vs. 0.524).

CONCLUSION:

This study suggests that bioimpedance spectroscopy could replace physical examination for estimating body fluid status in hyponatremia. In addition, bioimpedance spectroscopy might correspond better with clinical diagnosis than physical examination in the estimation of body fluid status in hyponatremia.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Exame Físico / Análise Espectral / Líquidos Corporais / Hipovolemia / Diagnóstico / Hiponatremia / Métodos Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2014 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Exame Físico / Análise Espectral / Líquidos Corporais / Hipovolemia / Diagnóstico / Hiponatremia / Métodos Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2014 Tipo de documento: Artigo