Your browser doesn't support javascript.
loading
Diagnostic value of 64-slice spiral CT colonography in TN staging of colorectal carcinomas / 中国医学影像技术
Article em Zh | WPRIM | ID: wpr-471676
Biblioteca responsável: WPRO
ABSTRACT
Objective To assess the value of 64-slice CT colonography (CTC) in preoperative TN staging of colorectal carcinomas. Methods One hundred and sixty-eight patients with suspected colorectal neoplasm underwent 64-slice spiral CTC after bowel cleaning and rectal air insufflating, among them 91 patients were proved with surgical pathology and enrolled into this study, and CTC images were reviewed separately by two experienced radiologists for preoperative TN staging of the tumors. Results For CTC evaluation of T staging, the sensitivity, specificity and accuracy were 98.57% (69/70), 85.00% (17/20) and 92.31% (84/91), respectively. The sensitivity, specificity and accuracy of CTC N staging were 87.80% (36/41), 96.00% (48/50) and 82.42% (75/91), respectively. Conclusion 64-slice spiral CTC plays a significant role in the preoperative TN staging of colorectal carcinoma.
Palavras-chave
Texto completo: 1 Índice: WPRIM Tipo de estudo: Diagnostic_studies Idioma: Zh Revista: Chinese Journal of Medical Imaging Technology Ano de publicação: 2009 Tipo de documento: Article