Determination of Indigo and Indirubin in Baphicacanthus cusia from Different Producing Areas and Medicinal Parts by RP-HPLC / 医药导报
Herald of Medicine ; (12): 1363-1366, 2015.
Artigo em Chinês | WPRIM | ID: wpr-477971
ABSTRACT
Objective To establish a RP-HPLC method for determining indigo and indirubin in Baphicacanthus cusia from different producing areas and medicinal parts. Methods The separation was achieved by an Agilent TC-C18 Column (4.6 mm×250 mm, 5 μm) at 25 ℃ using methanol-water (75??25) as mobile phase at a flow rate of 1 mL??min-1.The detection wavelength was 290 nm. Results Indigo had a good linear relationship with peak area at range of 0. 051 3-0.820 8 μg (r=0.999 3).The recovery rate was 99.00% and RSD was 1.30% (n=6).Indirubin had a good linear relationship with peak area at range of 0.049 5-0.792 0 μg (r=0.999 9).The recovery rate was 98.88% and RSD was 1.51% (n=6). Conclusion The contents of the two components are obviously different in Baphicacanthus cusia because of different places or medicinal parts. The proposed method is simple, rapid and reliable. This method for determination of indigo and indirubin in Baphicacanthus cusia by RP-HPLC provides a basis for quality control of Baphicacanthus cusia.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Herald of Medicine Ano de publicação: 2015 Tipo de documento: Artigo

Similares