Your browser doesn't support javascript.
loading
Application Value of Ablation Catheter for Pacemaker Atrial Lead Restoration in Patients With Atrial Lead Dislodgement After Pacemaker Implantation / 中国循环杂志
Chinese Circulation Journal ; (12): 993-995, 2015.
Artigo em Chinês | WPRIM | ID: wpr-479359
ABSTRACT

Objective:

To explore the application value of ablation catheter for pacemaker atrial lead restoration in relevant patients.

Methods:

A total of 6 patients with atrial lead dislodgement after pacemaker implantation were selected for our study. The atrial lead restoration was conducted by using ablation catheter via femoral vein pathway.

Results:

The average operational time was (15.0 ± 3.7) min which was obviously less than traditional operational time. The position of electrode restoration was ideal with well immobilization.

Conclusion:

Ablation catheter is feasible for arial lead restoration in patients with atrial lead dislodgement after pacemaker implantation.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Circulation Journal Ano de publicação: 2015 Tipo de documento: Artigo