Your browser doesn't support javascript.
loading
A comparison of degree of precision of auscultation, partial pressure of carbon dioxide in end-expiration, and transillumination technique in verifying accurate position of endotracheal tube / 中华危重病急救医学
Chinese Critical Care Medicine ; (12): 826-830, 2015.
Artigo em Chinês | WPRIM | ID: wpr-481349
ABSTRACT
ObjectiveTo evaluate the effect of auscultation, partial pressure of carbon dioxide in end-expiration (PETCO2), transillumination technique to judge whether the endotracheal tube is misplaced into the esophagus. Methods A blinded randomized controlled trial was conducted. Sixty patients with American Society of Anesthesiology (ASA) gradeⅠ-Ⅱundergoing endotracheal intubation in Fengxian Central Hospital admitted from September 2014 to February 2015 were enrolled. Two endotracheal tubes with the same size were respectively inserted into the trachea and esophagus for the same depth after general anesthesia by the same person. Two blinded anesthetists with different experience checked the tube position using three methods including auscultation, PETCO2, and transillumination technique, respectively. The order of the tubes tested (trachea or esophagus) and the method used were randomized according to randomise numbers table. The experienced anesthetists conducted the test first, followed by an inexperienced anesthetist conducting the same methods. The numbers of right and wrong determinations with different methods by different anesthetists were recorded.Results Sixty patients underwent the procedures for 180 times, with intratracheal intubation for 90 times, and esophageal intubation for 90 times. It was shown that the results were not different in two groups [96.7% (174/180) vs. 92.2% (166/180),χ2 = 3.500,P = 0.057]. By using auscultation, the correct rate of experienced anesthetist was higher than that of inexperienced (95.0% vs. 78.3%,χ2 = 5.786,P = 0.013). Using PETCO2, both anesthetists were correct in all cases, and the accuracy was 100%. Using transillumination, the experienced anesthetist was mistaken in 3 cases (accuracy was 95.0%), while the inexperienced mistook in 1 case (accuracy was 98.3%), and no significant difference was found between two groups (χ2 = 0.500,P = 0.250). The correct rate of using transilluminaion was significantly higher than that of using auscultation (χ2 = 7.563,P = 0.004). The sensitivity and specificity of the auscultation was 70.0% and 80.0%, that of transillumination technique was 96.7% and 93.3%,and PETCO2 was 100%, respectively, for two groups.ConclusionsPETCO2 is the most reliable method for determining tube position, and it is superior to auscultation and transilluminaion. Transillumintaion technique is superior to auscultation, irrespective of anesthetists' experience, while the accuracy of auscultation showed an obvious relationship with the anesthetists' experience.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Ensaio Clínico Controlado Idioma: Chinês Revista: Chinese Critical Care Medicine Ano de publicação: 2015 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Ensaio Clínico Controlado Idioma: Chinês Revista: Chinese Critical Care Medicine Ano de publicação: 2015 Tipo de documento: Artigo