Evaluation of the VIDAS Anti-HCV Assay for Detection of Hepatitis C Virus Infection
Annals of Laboratory Medicine ; : 550-554, 2016.
Artigo em Inglês | WPRIM | ID: wpr-48261
ABSTRACT

BACKGROUND:

Anti-hepatitis C virus antibody (anti-HCV) assays are recommended for screening HCV-infected persons. The VIDAS Anti-HCV Assay (bioMérieux, France), based on the enzyme-linked fluorescence test principle, was recently introduced in Korea. We evaluated the clinical performance of the VIDAS assay.

METHODS:

One hundred HCV-positive and 1,002 HCV-negative blood samples confirmed by Architect anti-HCV (Abbott Laboratories, USA) and COBAS TaqMan HCV real-time PCR (Roche Diagnostics, USA) or the Procleix Ultrio Plus Assay (Gen-Probe Incorporated, USA) were obtained from the Human Serum Bank (HSB) and tested by VIDAS. In case of discrepant results, we conducted a recombinant immunoblot assay (RIBA).

RESULTS:

The agreement rates for known HCV-positive and HCV-negative samples between the VIDAS assay and the HSB testing were 100% (95% confidence interval [CI] 96.4-100%) and 99.5% (95% CI 98.8-99.8%), respectively. One of the five discrepant samples was positive for Core 2+ and NS3-2 2+ reactivity, two samples were negative, and the other two were indeterminate regarding NS4 2+ reactivity in RIBA. We observed a significant but weak positive correlation between the titers of VIDAS and Architect assays (r=0.315, P<0.001).

CONCLUSIONS:

The VIDAS anti-HCV assay, developed on the VIDAS automated immunoassay platform based on the ready-to-use, single-sample test concept may be useful in small-to-medium-sized laboratories. It showed good agreement with Architect anti-HCV and COBAS PCR assays and is therefore useful for detection of HCV infection. Weakly test-positive (ambiguous) samples require additional testing by another anti-HCV, RIBA, or HCV RNA assay.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Kit de Reagentes para Diagnóstico / Automação / Imunoensaio / Immunoblotting / Sensibilidade e Especificidade / Hepatite C / Anticorpos Anti-Hepatite C Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Inglês Revista: Annals of Laboratory Medicine Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Kit de Reagentes para Diagnóstico / Automação / Imunoensaio / Immunoblotting / Sensibilidade e Especificidade / Hepatite C / Anticorpos Anti-Hepatite C Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Inglês Revista: Annals of Laboratory Medicine Ano de publicação: 2016 Tipo de documento: Artigo