Clinical and Radiogical Outcomes of Endovascular Detachable Coil Embolization in Paraclinoid Aneurysms : A 10-Year Experience
Journal of Korean Neurosurgical Society ; : 5-10, 2009.
Artigo em Inglês | WPRIM | ID: wpr-48296
ABSTRACT

OBJECTIVE:

Direct surgical clipping of paraclinoid aneurysms poses technical challenges to even very experienced neurosurgeons, making endovascular treatment an alternative treatment modality in many centers. We have therefore retrospectively evaluated the safety and efficacy of endovascular detachable coil embolization of paraclinoid aneurysms.

METHODS:

From June 1997 to June 2007, 65 patients underwent endovascular detachable coiling for 67 paraclinoid aneurysms (of which 9 were ruptured and 58 were unruptured) in our institute. Their medical records, radiological images and readings, and operation records were reviewed retrospectively.

RESULTS:

After the initial embolization procedure, complete occlusion was achieved in 29 (43.3%) of the aneurysms treated by endovascular detachable coiling. Six aneurysms required retreatment, with two each requiring one, two, or three additional endovascular procedures. Fifty-five (82.1%) aneurysms were measured by three-dimensional time of flight (TOF) magnetic resonance images (MRI) or transfemoral cerebral angiography (TFCA) at a mean follow-up of 29.7 months (range from 4 to 94 months), with 39 aneurysms (70.9%) showing complete occlusion. Thromboembolic events (3.8%) were the most frequent complication. Rupture did not occur during or after any of the procedures. According to the Glasgow Outcome Scale (GOS), 98.4% of the patients treated by coil embolization had a score of 4 or 5.

CONCLUSION:

Our results indicate that endovascular detachable coiling is a safe and effective treatment modality in paraclinoid aneurysms.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Leitura / Ruptura / Instrumentos Cirúrgicos / Angiografia Cerebral / Espectroscopia de Ressonância Magnética / Prontuários Médicos / Estudos Retrospectivos / Seguimentos / Retratamento / Escala de Resultado de Glasgow Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Journal of Korean Neurosurgical Society Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Leitura / Ruptura / Instrumentos Cirúrgicos / Angiografia Cerebral / Espectroscopia de Ressonância Magnética / Prontuários Médicos / Estudos Retrospectivos / Seguimentos / Retratamento / Escala de Resultado de Glasgow Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Journal of Korean Neurosurgical Society Ano de publicação: 2009 Tipo de documento: Artigo