ABSTRACT

BACKGROUND:

Posterior lamina resection often causes loss of spinal stability, so screw rod internal fixation technology is needed to maintain the stability of lumbar spine. Finite element analysis can be used to simulate the stress distribution of the spine and internal fixation system after spinal surgery.

OBJECTIVE:

To build three-dimensional finite element model of spinal L1 to L3, analyze the spinal stability and stress distribution after the total laminectomy and insertion of bilateral pedicle screw using finite element method.

METHODS:

L1-L3 CT data could be colected from an adult healthy male volunteer. Mimics14.01, 3-matic(V6.0) and Ansys 15.0 could be used to set up the intact lumbar spine finite element model of L1-L3 (group A), the L1-L3 finite element model after L2 total laminectomy (group B), and the finite element model of L2 total laminectomy and insertion of bilateral pedicle screw (group C). We used software to simulate flexion, extension, lateral bending and axial rotation, and three kinds of models received finite element analysis. RESULTS AND

CONCLUSION:

(1) Based on the maximum of Von Mises under different motion states, the maximum stress was significantly lower in group A than in group B (P< 0.05). The maximum stress was significantly lower in group B than in group C (P < 0.05). (2) Based on the total deformation under different motion states, the total deformation was significantly lower in group A than in group B (P < 0.05). The total deformation was significantly lower in group C than in groups A and B (P < 0.05). (3) After the total laminectomy, vertebral body stress increased, especialy in the lamina, pedicle and joints. The range of motion of the vertebral body increased, which influenced the stability of the vertebral body. Internal fixation could decrease range of motion. Stress concentrated on the screw. Stress on the vertebral plate and pedicle decreased. The stability of vertebral body increased. Excessive stress concentrated on screw system wil increase the risk of screw breakage.