Your browser doesn't support javascript.
loading
The clinical application and value of transcranial doppler monitoring senile cerebral blood flow autoregulation in elderly / 中国综合临床
Clinical Medicine of China ; (12): 47-50, 2016.
Artigo em Chinês | WPRIM | ID: wpr-489159
ABSTRACT
Objective To study the clinical application and value of transcranial Doppler (TCD) monitoring senile cerebral blood flow autoregulation in elderly.Methods Two hundred cases patients with elderly hypertension and 200 cases normal eldly from May 2011 to December 2014 in the Second People 's Hospital of Fengrun District of Tangshan were chosen as hypertension group and control group.Cerebral artery peak systolic velocity,supine with a vertical artery in the brain(MCA) cerebral blood flow difference (CBFV) and X-W wave duration, cerebrovascular hemodynamic parameters of two group were monitored by TCD method and compared.Results The peak values of left vertebral artery (LVA), right vertebral artery (RVA), the left coronary artery(LCS), and right vertebral artery(RCS) of hypertension group were significantly lower than those in the control group((38.01±12.42) cm/s vs (45.21±8.95) cm/s, (35.54±13.25) cm/s vs (43.52±7.06) cm/s, (66.12±9.52) m/s vs (76.54±8.19) cm/s, (71.24± 11.25) cm/s vs (77.98± 10.74) cm/s, (55.34 ±14.52) cm/s vs (61.24±12.58) cm/s,(48.12±15.24) cm/s vs (58.46±18.85) cm/s;t=4.6821, 5.6987,6.2589,4.3671,2.2854,4.9875;P< 0.01).The peak Vp, the difference between the horizontal and vertical position CBFV, X-W wave duration, the parameter of DR, Cp, C, Co, Zc, Wv of arterial blood vessels (left internal carotid artery (LICA), right internal carotid artery (RICA), left middle cerebral artery (LMCA), right middle cerebral artery(RMCA) ,left anterior cerebral artery(LACA), right anterior cerebral artery(RACA), left anterior cerebral artery (LOA), right middle cerebral artery (ROA)) of hypertension group were significantly higher than those of control group((96.38±18.85) cm/s vs (83.56±13.41) cm/s, (103.04±35.42) cm/s vs (85.62±29.63) cm/s, (99.85±23.54) cm/s vs (83.12±22.67) cm/s, (102.84± 16.42) cm/s vs (86.23 ±21.34) cm/s, (85.06± 15.36) cm/s vs (73.16± 10.35) cm/s, (85.64± 15.34) cm/s vs (70.52± 18.56) cm/s, (34.85±8.74) cm/s vs (28.56±7.85) cm/s, (35.12± 11.20) cm/s vs (30.05± 6.88) cm/s, (7.22 ± ±2.54) cm/s vs (2.78± 1.87) cm/s, (23.74±5.23) cm/s vs (20.85±4.35) cm/s, (378.35±35.12) Pa? s/cm vs (314.53±36.21) Pa? s/cm, (8.16± 0.62) P/kPa vs (7.25± 0.68) P/kPa, (0.41 ± 0.05) ml/kPa vs (0.33±0.06) ml/kPa, (1.15±0.16) mL/kPa vs (0.84±0.13) ml/kPa, (346.13±42.63) dyn? s/cm5 vs (241.68±50.21) dyn? s/cm5, (21.47± 3.85) V/(cml? s) vs (11.24 ± 3.67) V/(cml? s);t =5.8954, 4.2589,4.8792,6.3985,6.3874,6.9852,5.6387,4.6892,6.0387,4.8562, 11.475,8.041,12.422, 11.820, 12.854,20.412;P<0.01).Conclusion The function of automatic adjustment shows obvious abnormal cerebral blood flow in patients with hypertension, andthe TCD technology can response of cerebral blood flow autoregulation,which has important clinical value for diagnosis and treatment of cerebral infarction, stroke and other cardiovascular and cerebrovascular diseases.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Clinical Medicine of China Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Clinical Medicine of China Ano de publicação: 2016 Tipo de documento: Artigo