Objective To perform the serological identification of anti‐E and anti‐Mur found in the detection before blood trans‐fusion and to analyze its clinical significance in blood transfusion .Methods The reaction pattern of serum with the antibody screen‐ing spectrum was detected by using the micro‐column gel method for identifying the antibody type and specificity .Results The 3 kinds of antibody anti‐E IgG combined with anti‐Mur IgG + IgM existed in the serum of 2 patients .Conclusion Anti‐E and anti‐Mur all are easier to lead to the hemolytic blood transfusion reaction .Selecting the suitable donor on the basis of the accurate anti‐body identification can provide guarantee for blood transfusion safety .