Objective To evaluate the value of CT guided percutaneous transthoracic needle biopsy (PTNB) for the diagnosis of lung ground‐glass opacity (GGO) with a Meta‐analysis .Methods Relevant English and Chinese language studies were searched on the PubMed ,EMBASE ,EBSCO ,OVID ,CNKI ,CBM ,VIP and WANFANG databases ,respectively .Data were calculated with software of Stata 12 .0 and Meta‐Disc 1 .4 .Results 6 of 82 retrieved studies were included (n=341) .The pooled sensitivity ,specifici‐ty ,LR+ ,LR- ,DOR ,AUC and 95% CI were 0 .92(0 .86-0 .95) ,0 .98(0 .85-1 .00) ,49 .03(5 .72-420 .18) ,0 .08(0 .05-0 .15) , 586 .24(65 .18-5 272 .83) and 0 .99(0 .98-1 .00) ,respectively .Conclusion CT guided PTNB can be used as one of the primary examination modalities for lung GGO with moderate sensitivity and specificity .