Your browser doesn't support javascript.
loading
Determination of glucosamine hydrochloride and related substances in glucosamine and indometacin enteric-coated capsules by HPLC-ELSD / 中国生化药物杂志
Chinese Journal of Biochemical Pharmaceutics ; (6): 194-196, 2016.
Artigo em Chinês | WPRIM | ID: wpr-496383
ABSTRACT
Objective To establish an high performance liquid chromatography-evaporative light scattering detector (HPLC-ELSD) method for determination of glucosamine hydrochloride and its related substances in glucosamine and indometacin enteric-coated capsules.Methods Separation was carried out on a Inertsil C8 Column (250 mm ×4.6 mm,5μm) with a mobile phase composed of acetonitrile-water(70∶30) at a flow rate of 1.0 mL/min and the column temperature was 25℃.Results The linear ranges of calibration curve was 25 -312.5 μg/mL(r=0.9991, n=6).The average recovery was 98.0%, and the relative standard deviation was 1.3%( n =5 ) .The glucosamine hydrochloride was stable with acid destruction, but unstable with alkali, heat and strong light destruction.Conclusion The method is simple, accurate and reproducible for determination of glucosamine hydrochloride and related substances.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Biochemical Pharmaceutics Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Biochemical Pharmaceutics Ano de publicação: 2016 Tipo de documento: Artigo