ABSTRACT
Objective To observe the preliminary clinical results and safety of 27-gauge microincision vitrectomy surgery for partial vitreoretinal diseases.Methods A total of 13 patients (13 eyes) who underwent 27-gauge microincision vitrectomy surgery were enrolled.The follow-up period was 6 to 12 months.Preoperative and postoperative visual acuity and intraocular,total operative time,cutting time for removing vitreous,wound healing status,intraoperative and postoperative complications were observed.Results Mean best corrected visual acuity improved from preoperative (1.26±0.66) logMAR (0.10±0.09) to postoperative (0.63±0.52) logMAR (0.35±0.24),and the difference was statistically significant (t=2.743,P=0.018).The difference of mean preoperative intraocular pressure (IOP),IOP of postoperative day 1,day 5,one month and final postoperative visit were not statistically significant (F=0.593,P>0.05).The mean total operative and cutting times were (36.38±14.97) min and (10.12±3.54) min respectively.Postoperative scleral incision showed linear closure,no cases of postoperative sclerotomyrelated complications such as wound dehiscence,vitreous incarceration and subcoujunctival fluid were observed.No intraoperative and postoperative complications of iatrogenic retinal breaks,endophthalmitis,choroidal detachment,retinal detachment and vitrous hemorrhage were observed.Conclusions The 27-gauge microincision vitrectomy surgery can improve postoperative visual acuity for treatment of vitreoretinal diseases and induce fewer sclerotomyrelated complications,which maybe a safer surgical approach.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: International Journal of Biomedical Engineering Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: International Journal of Biomedical Engineering Ano de publicação: 2016 Tipo de documento: Artigo