Effects of Additives in Blood Collection Tubes on Testing the Alcohol Concentra-tion in Blood Samples / 法医学杂志
J. forensic med
; Fa yi xue za zhi;(6): 452-455, 2014.
Article
em Zh
| WPRIM
| ID: wpr-500292
Biblioteca responsável:
WPRO
ABSTRACT
Objective To discuss blood collection tubes with different additives and their effects on the testing results of alcohol concentration in blood sam ples. Methods Blood sam ples from 10 volunteers were collected 2 hours after drinking with seven different types of disposable vacuum blood collection tubes, including ordinary tube without anticoagulant, coagulant tube, separating gel-coagulant tube, sodi-um citrate (1∶4) tube, sodium citrate (1∶9) tube, sodium citrate (9∶1) tube and EDTA-K2 tube. The al-cohol concentrations in these blood sam ples were analyzed by headspace gas chrom atography. Results The concentration testing results of the sam e blood sam ples in different types of tubes were different from one to another. The sequence was as follows:separating gel-coagulant tube>coagulant tube>ordi-nary tube without anticoagulant>EDTA-K2 tube>sodium citrate (1∶9) tube>sodium citrate (1∶4) tube, whereas the results of the sam e blood sam ple in sodium citrate (1∶9) tube and sodium citrate (9∶1) tube showed no obvious difference. Conclusion It is better to collect a suspicious drunk driver’s blood sam-ple using a disposable vacuum blood collection tube, with the EDTA-K2 tube being preferred.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Fa yi xue za zhi
/
J. forensic med
Ano de publicação:
2014
Tipo de documento:
Article