Your browser doesn't support javascript.
loading
To analyze the performances and the related measurement values for femoro-acetabular impingement on MSCT / 实用放射学杂志
Journal of Practical Radiology ; (12): 91-94, 2017.
Artigo em Chinês | WPRIM | ID: wpr-510230
ABSTRACT
Objective To investigate the performances and characteristics of femoro-acetabular impingement (FAI)on MSCT. Methods Hips jointed MSCT scans of 109 cases (as case group)and the other 120 cases (as control group)were analyzed retrospec-tively,to analyze the anatomy and osseous abnomality of FAI.Alpha angle,offset,CE angle were measured.The data were tested by using t test and ANOVA test.Results There were 57 cases of osseous protuberance at the femoral head and neck joint,26 cases of the offset reduction,17 cases of over-coverage acetabulum,41 cases of over-deep acetabulum,20 cases of acetabular retroversion,57 cases of subcortical cystic degeneration at the femoral head and neck joint and 22 cases of subchondral cystic degeneration at the ace-tabulum margin.Significant statistical differences were found between case group and control group in alpha angle value,offset and CE angle (P<0.05).Multiple comparisons demonstrated that except results between the value of alpha angle of Cam-type and Mixed-type(P=0.071),Pincer-type and the control group(P=0.083)with no statistical significance,the differences between any other two groups reached statistical significance (P<0.05).Multiple comparisons demonstrated that except result between the value of offset of Cam-type and Mixed-type(P=0.561)with no statistical significance,the differences between any other two groups reached statistical significance (P<0.05).Multiple comparisons demonstrate that except results between the value of CE angle Pin-cer-type and Mixed-type (P=0.444),Cam-type and the control group (P=0.236)with no statistical significance,the differences be-tween any other two groups reached statistical significance (P<0.05).Conclusion Different type of FAI has its unique anatomical features.Alpha angle,offsetand CE angle for the diagnosis of FAI have important reference values.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Journal of Practical Radiology Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Journal of Practical Radiology Ano de publicação: 2017 Tipo de documento: Artigo