Your browser doesn't support javascript.
loading
The establishment of esophageal re-stenosis model by using esophageal stent implantation: observation in experimental rats / 介入放射学杂志
Journal of Interventional Radiology ; (12): 157-160, 2017.
Artigo em Chinês | WPRIM | ID: wpr-513492
ABSTRACT
Objective To evaluate the feasibility and safety of establishing benign proliferative esophageal stenosis model by using stent implantation in experimental rats.Methods A customized self-expanding,metallic and straight tubular stent was used in this experiment (5 mm in diameter and 15 mm in length),on both sides at the stent's middle part there was a protruding barb that was used as a fixation device.Twelve healthy Sprague Dawley (SD) rats were randomized divided into group A (blank control group) and group B (stent implantation group),with 6 rats in each group.Esophageal stent implantation was employed in the rats of group B,and esophageal radiography was separately performed immediately,one and 4 weeks after stent implantation.All the experimental rats were sacrificed 4 weeks after stent implantation.The normal esophageal tissue of the rats in group A and the esophageal tissue at stent site of the rats in group B were collected and sent for pathological examinations,including gross morphology,light microscopy,etc.Results Successful stent implantation was achieved in all rats of group B,and the esophageal radiography performed immediately,one and 4 weeks after stent implantation showed no esophageal stent displacement;no severe complications occurred during the operation or follow-up period.Compared with group A,esophageal radiography reexamination performed 4 weeks after stent implantation in group B revealed that esophageal stricture at stent segment,caused by benign tissue hyperplasia,could be observed.The esophageal stent segment was taken out,its lumen was obviously narrowed under gross observation,and typical benign hyperplasia could be seen under optical microscope examination.Conclusion Using esophageal stent implantation to establish esophageal stenosis model is safe and feasible in experimental rats.The use of esophageal stent with barbs can significantly reduce the incidence of stent displacement.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Ensaio Clínico Controlado Idioma: Chinês Revista: Journal of Interventional Radiology Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Ensaio Clínico Controlado Idioma: Chinês Revista: Journal of Interventional Radiology Ano de publicação: 2017 Tipo de documento: Artigo