OBJECTIVE:To establish HPLC method for simultaneous determination of estazolam and diazepam in serum METHODS:The mobile phase consisted of methanol-water-triethylamine-acetic acid(55∶45∶0 5∶0 35)and the ?max was 254nm Phenytoin was adopted as the internal standard The drugs were extracted by diethyl ether under the alkaline condition RESULTS:The calibrating curves of estazolam and diazepam were linear in the ranges of 0 52~38 62?g/ml and 0 50~40 16?g/ml respectively CONCLUSION:The method was appropriate for determination of estazolam and diazepam qualitatively and quantitatively in intoxication accident