Your browser doesn't support javascript.
loading
HPLC versus Gravimetric Analysis in the Determination of Sodium New Houttuyfonte Injection / 中国药房
China Pharmacy ; (12)1991.
Artigo em Chinês | WPRIM | ID: wpr-531531
ABSTRACT

OBJECTIVE:

To compare between the HPLC method and gravimetric analysis in the determination of the content of sodium new Houttuyfonte injection.

METHODS:

The content of sodium new Houttuyfonte injection was determined by HPLC and gravimetric analysis respectively.HPLC condition Zorba extent-C18 column(250 mm?4.6 mm,5 ?m) detected by UV(286 nm),and the mobile phase consisted of methanol-water-tetrabutyl ammonium hydroxide(70300.3).The procedure of gravimetric analysis was in line with state drug standard.

RESULTS:

The determination results were notably different between the two methods.

CONCLUSION:

Gravimetric analysis showed no specificity in the determination of sodium new Houttuyfonte injection.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Pharmacy Ano de publicação: 1991 Tipo de documento: Artigo