Your browser doesn't support javascript.
loading
Investigation and Analysis of Automatic Injection Drug Dispensing System in Inpatient Dispensary / 中国药房
China Pharmacy ; (12)1991.
Article em Zh | WPRIM | ID: wpr-533309
Biblioteca responsável: WPRO
ABSTRACT
OBJECTIVE:To optimize drug for injection dispensing model in order to supply reference for popularity of automatic injection drug dispensing system(AIDDS) in inpatient dispensary.METHODS:Two kinds of drug dispensing model were adopted in five departments.In 10 working days before and after application of AIDDS,the time of drug dispensing flow needed was recorded.The time of every drug dispensing step needed for single patient was recorded and analyzed to evaluate the benefit of system.RESULTS:After application of AIDDS,the drug dispensing time for single patient reduced from 1.5~2.1 min to 0.45~0.80 min.The drug dispensing efficiency was improved significantly,the extent of which was in positive correlation to amount of patient demanding drug dispensing.CONCLUSION:The application of AIDDS speedups drug for injection dispensing,shortens dispensing time and saves human resource.
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: China Pharmacy Ano de publicação: 1991 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: China Pharmacy Ano de publicação: 1991 Tipo de documento: Article