Your browser doesn't support javascript.
loading
Validation of Microbial Limit Test for Compound Clindamycin Hydrochloride Gel / 中国药房
China Pharmacy ; (12)2007.
Artigo em Chinês | WPRIM | ID: wpr-534258
ABSTRACT

OBJECTIVE:

To establish microbial limit test for Compound clindamycin hydrochloride gel and to carry out the validation of three methods.

METHODS:

According to the appendices volumeⅡof Chinese Pharmacopeia(edition 2005),microbial limit test which contained routine test,medium dilution method and membrane-filter method was adopted to validate Compound clindamycin hydrochloride gel.Recoveries of three methods were compared to make sure the suitable validation method.

RESULTS:

In routine test,recovery of trial bacteria was lower than 70%and controlled bacteria couldn't be found out.In medium di-lution method,recovery of trial bacteria was higher than 70%and still lower than the recovery of diluents.In membrane-filter method,recovery of trial bacteria was higher than 90%,and controlled bacteria grew well.Membrane-filter method could eliminate inhibition effect of Compound clindamycin hydrochloride gel on bacteria.

CONCLUSION:

Membrane-filter method is effective and practical for microbial limit test of Compound clindamycin hydrochloride gel.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Pharmacy Ano de publicação: 2007 Tipo de documento: Artigo