Your browser doesn't support javascript.
loading
Solitary Pulmonary Nodule:Dynamic Spiral CT Scan of Thin Collimation with Pathology Study / 实用放射学杂志
Journal of Practical Radiology ; (12)2001.
Artigo em Chinês | WPRIM | ID: wpr-537287
ABSTRACT
Objective To evaluate the diagnosis and differentiation of solitary pulmonary nodule (SPN) using dynamic spiral CT scan of thin collimation.Methods The thin collimation no-enhanced CT scan and contrast enhanced scan in 30 seconds,1 minute,1 minutes,2 minutes,5 minutes,10 minutes,and 15 minutes after administration of media 100 ml were performed in 38 cases. Results The mean enhanced CT numbers of lung cancer and inflammatory pseudotumor were much higher than that of tuberculosis(TB) and hamartoma and statistically significant in different time of enhancement;20 HU was the threshold for a positive test,the sensitivity was 100% and the specificity was 96%.In time-attenuation curve analysis,lung cancer reached peak enhancement about 2 minutes,inflammatory pseudotumor in 5 minutes and keep longer enhanced time than that of lung cancer.No marked enhancement in SPN of TB and harmatoma,but ring-shaped enhancement can be seen in some of TB.More valuable imaging signs were found with thin collimation scan and more accurate to measure the CT numbers than traditional scan.Conclusion Dynamic spiral CT scan of thin collimation is a very valuable method for diagnosis and differentiation of SPN.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Journal of Practical Radiology Ano de publicação: 2001 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Journal of Practical Radiology Ano de publicação: 2001 Tipo de documento: Artigo