Your browser doesn't support javascript.
loading
Clinical Application in Diagnosis of Pulmonary Embolism by Multiple Spiral CT Angiography / 实用放射学杂志
Journal of Practical Radiology ; (12)2001.
Artigo em Chinês | WPRIM | ID: wpr-540216
ABSTRACT
Objective To evaluate the effectiveness of multiple spiral CT angiography in diagnosis of pulmonary embolism.Methods 16 patients clinically suspected of pulmonary embolism underwent multiple spiral CT angiography.Emboli were found in the 8 patients of all on multiple spiral CT angiography.5 of the patients were reexamined with this method 20 to 30 days after thrombolysis. Results In 8 patients with pulmonary embolism,43 vessels were involved with pulmonary embolism.The presence of pulmonary embolism on CT was seen as a total occlusion,partial filling defect,mural filling defect et al;dilated of pulmonary artery trunk;all signs with deceleration of pulmonary blood or “mosaic sign”. 5 patients were reexamined with this method.The emboli dissoved partly or entirely.Conclusion Multiple spiral CT angiography is a noninvasive and effective method for examining pulmonary embolism.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo diagnóstico Idioma: Chinês Revista: Journal of Practical Radiology Ano de publicação: 2001 Tipo de documento: Artigo