Determination of Acetic Acid Peroxide in Disinfectant by Gas Chromatography / 环境与健康杂志
Journal of Environment and Health
;
(12)1989.
Artigo
em Chinês
| WPRIM
| ID: wpr-540382
ABSTRACT
Objective To established a method for determining the acetic acid peroxide in disinfectant. Methods The acetic acid peroxide determined by gas chromatography using FFAP fixative solution, Chromosorb W-AW DMCS column and FID detector. Results The detection limit was 0.001%.The linear range was from 0.01% to 25%.The recovery rate was 93%-102%?RSD was less than 2.93%. Conclusion The method is simple, rapid, sensitive and has a good selectivity. The sample can be directly detected without separation.