Determination of Aluminium in Water By Be Ryllon Ⅲ Spectrophotometry / 环境与健康杂志
Journal of Environment and Health ; (12)1989.
Artigo em Chinês | WPRIM | ID: wpr-540385
ABSTRACT
Objective To Study the method for determination of aluminium in water by spectrophotometry of Be ryllon Ⅲ. Methods Be ryllon Ⅲ reacts on aluminium in oppropriate temperature and acidity in water and produces a red complex compound?The red complex compound can be determined by spectrophotometry. Results The optimum reaction temperature was 85 ℃, the optimum reaction time was 5 min, pH of buffer was 6.1, Beer's law was obeyed in the concentration range of 0-0.02 mg/L for aluminium, rates of recovery were 80.0%-96.0% and RSD was 0.70%. Conclusion This method is accurate, simple, sensitive and repeatable.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Journal of Environment and Health Ano de publicação: 1989 Tipo de documento: Artigo