Your browser doesn't support javascript.
loading
HPLC determination of mycophenolic acid in serum of early period of renal transplant patients / 西安交通大学学报(医学版)
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6)2004.
Artigo em Chinês | WPRIM | ID: wpr-548125
ABSTRACT
Objective To establish a high-performance liquid chromatography method for determination of mycophenolic acid in human plasma.Methods The method was performed with C18 column(3.9mm?300mm).The mobile phase consisted of 40mmoL/L TBA solution-acetonitrile adjusted to pH 4 with orthophosphoric acid(55∶45,V∶V),with a flow rate 0.8mL/min.The UV detection wavelength was 254nm.Plasma samples were extracted with methanol.Results The linear concentration of the calibration curve ranged from 0.8 to 51.45mg/L(r=0.9998).The relative recoveries were between 95.5% and 109.2%,and the extraction recoveries were more than 90%.Relative standard deviation(RSD) of intraday and interday assays were both less than 10%.Conclusion The method is proved to be reliable and simple for monitoring mycophenolic acid in human plasma and bioequivalence research.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Journal of Xi'an Jiaotong University(Medical Sciences) Ano de publicação: 2004 Tipo de documento: Artigo