[Objective] To compare anatomical dynamic hip lock plate with Gamma nail internal fixation in terms of the early intermediate clinical effect of the unstable intertrochanteric femoral fractures. [Methods]From January 2003 to August 2008, 69 patients with unstable intertrochanteric femoral fractures were fixed with plate (n=34)and Gamma nail(n=35).They were randomized into two treatment groups.A retrospective comparison was made between the two differet fixation devices in terms of operation time,blood loss,intraoperative and postoperative complications,frequency of exposure to X-ray,healing time of fracture and functional recovery of hip-joint.[Results]Comparing with Gamma nail,cases with anatomical dynamic hip lock plate experienced fewer X-ray during operation and had fewer postoperative complications,and the differences had statistical significance(P