Treatment of metacatpal and phalangeal fractare with AO mini-plate / 中国基层医药
Chinese Journal of Primary Medicine and Pharmacy ; (12)2006.
Artigo em Chinês | WPRIM | ID: wpr-558439
ABSTRACT
Objective To investigate the freatment outcome of internal fixation of the metacarpal and phalanx fracture using the pure fitanium mini plate.Methods 42 cases(78 lesions) of metacarpal and phalanx fracture were involved.Internal fixation with custom made pur titanium mini plate was done.Results Postoperative follow up rauged from 3 to 14 months and the fracture was healed in 42 cases.The bone union of roantgenographic eridence was 6 to 12 weeks.According to the functional evaluation of TAM ascles the excellent and good rate was 85.7%.Conclusion The AO mini-plate in treatment of the metacarpal and phalax fracture has a firm fixation.It is an optimal strategy for metarcarpal and phalanx fracture.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Primary Medicine and Pharmacy Ano de publicação: 2006 Tipo de documento: Artigo

Similares