Diagnostic value of multi-slice spiral CT for lesions in middle and inner ears / 第三军医大学学报
Journal of Third Military Medical University
; (24)2003.
Article
em Zh
| WPRIM
| ID: wpr-564110
Biblioteca responsável:
WPRO
ABSTRACT
Objective To assess the clinical value of multi-slice CT(MSCT)in showing the ear lesions.Methods MSCT high resolution scan images of 52 ears of 11 normal adult and 15 patients with hearing loss were reconstructed,by bone plus with 0.625 mm collimation,9.6 cm small field of vision(FOV)and 0.3 mm reconstruction interval before volume rendering(VR)and multiplanar reformation(MPR)were performed.Results VR,MIP and MPR images of 40 normal ears clearly showed the complicated anatomic structures.VR,MIP and MPR images of twelve abnormal ears displayed 3 ears of malformations of crus longum incudis,1 ear of destructed semicircular canals,2 ears of malleus dysplasia,2 ears of fusion of incudostapedial joint,2 ears of bony atresia of external auditory complicated with auditory ossicles dysplasia,and 2 ears of crus stapedis dysplasia.MPR is easier to manipulate than VR that has three dimensional effect butis difficult to handle.Conclusion HRCT images,combined with post-processing technique of VR,MIP and MPR,can clearly show the anatomic structures and lesions of middle and inner ears.
Texto completo:
1
Índice:
WPRIM
Tipo de estudo:
Diagnostic_studies
Idioma:
Zh
Revista:
Journal of Third Military Medical University
Ano de publicação:
2003
Tipo de documento:
Article