Your browser doesn't support javascript.
loading
Experimental study of replacement of artificial tracheal prosthesis by two-stage procedure with memory-alloy mesh / 中华胸心血管外科杂志
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12)2003.
Artigo em Chinês | WPRIM | ID: wpr-572015
ABSTRACT

Objective:

To make an artificial trachea, which can really healed with native trachea.

Methods:

20 dogs are randomized into a pedicle group and a nonpedicle group. 6 cm cervical trachea was resected and replaced with "sandwich" artificial trachea made from memory alloy meshes by two-stage operative procedure. Survival period and stenosis of anastomosis were recorded.

Results:

Seven dogs in pedicle group survived well and another three were dead. The cause of death was anastomosis stricture in 1 and infection in 2. All dogs in nonpedicle group were dead within four weeks because of stenosis or infection.

Conclusion:

Two-stage operative pedicle "sandwich" artificial trachea made from memory alloy mesh is up to now the closest artificial trachea to human native trachea. It could be applied clinically.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Ensaio Clínico Controlado Idioma: Chinês Revista: Chinese Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2003 Tipo de documento: Artigo