Your browser doesn't support javascript.
loading
Modified extracardiac conduit Fontan procedure for heterotaxia syndrome with complex congenital heart disease / 中华胸心血管外科杂志
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12)2003.
Artigo em Chinês | WPRIM | ID: wpr-573686
ABSTRACT
Objective To review and summarize the experiences of modified extracardiac conduit Fontan operation for heterotaxia syndrome with complex congenital heart disease. Methods There were 11 patients with cynosis complex congenital heart disease, 9 were aspleenia syndrome (right atrium isomerism, including 6 single ventricle with common atrioventricular valve, 2 double outlet right ventricle with atrioventricular discordance, and 1 corrected transposition of the great arteries), and 2 were polyspleenia (left atrium isomerism, double outlet right ventricle with common atrioventricular valve). The mean age was (6.3?3.7)year-old, the mean body weight was (21.0?5.5)kg. 3 patients underwent one-stage modified extracardiac conduit Fontan procedure, 8 patients after bi-directional Glenn operation underwent two-stage procedure. Results During early postoperative period, two patients had low cardiac output syndrome, 1 renal dysfunction; and 1 supraventricle tachycardiac. The time of chest drainage (120*!ml/d) was more than 10 days in 2 patients. 2D-echo showed that superior vena cava blood flow rate was 0.6 to 0.8 m/s, inferior vena cava flow rate was 0.3 to 0.4 m/s. Oxygen saturation were from 0.92 to 0.95 in room air in 9 patients, 2 patients were under 0.86. The exercise capacity was significantly improved. All patients were survived and no early death. At follow-up ranging from 6 months to 2 years, supra vena cava blood flow rate was 0.8*!m/s, inferior vena cava flow rate is 0.4 to 0.7*!m/s. There was no thrombus formation in the conduit. The diameter of fenestration was 0.34*!cm and blood flow from right to left. No pulmonary vein drainage obstruction. Heart function was normal. No atrial arrhythemia were detected. The oxygen saturation in the room air was more than 0.90. No chronic effusion and protein-losing enteropathy, no mid-term death. Conclusion Modified extracardiac conduit Fontan operation is suited for heterotaxia syndrome with complex congenital heart disease. The incidence of arrhythemia is low.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2003 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2003 Tipo de documento: Artigo