Synchrotron Microangiography of the Rat Heart Using the Langendorff Model
Korean Circulation Journal ; : 462-467, 2008.
Artigo em Inglês | WPRIM | ID: wpr-57382
ABSTRACT
BACKGROUND AND

OBJECTIVES:

The ability to study microvessels of a beating heart in real time at the level of the capillary is essential for research. However, there are no proven methods currently available to achieve this. The conventional absorption-contrast agents have limitations for studying capillaries. Microangiography with using synchrotron phase-contrast X-ray technology and no contrast agent has recently been reported on. We tried to verify this previous report, and we wanted to visualize the microvessels of a rat heart using air as a contrast agent. MATERIALS AND

METHODS:

We made the Langendorff apparatus in a hutch of the Pohang Accelerator Laboratory. The images were obtained with a white beam and a monochromatic beam. The visual images were magnified using 3x and 20x optical microscope lenses, and the images were captured with a charge-coupled device camera.

RESULTS:

We could not duplicate the previously reported findings in which microvessels were visualized without the use of contrast agent. But with using air as a contrast agent, the microvasculature of rat hearts was clearly identified at a spatial resolution of 1.2 microm. Air being absorbed inside a capillary was also observed. Vessels under 10 microm diameter were unable to be visualized with using iodine as a contrast agent.

CONCLUSION:

Phase contrast imaging already allows spatial resolution of 1 microm, which is enough to inspect capillaries. We were able to obtain images of cardiac capillaries with using air as a contrast agent. Yet air has the fatal limitations in that it causes embolism and ischemia. A more suitable contrast agent or imaging method needs to be developed in order to study the microvessels of a beating heart.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Capilares / Síncrotrons / Meios de Contraste / Embolia / Microvasos / Coração / Iodo / Isquemia Tipo de estudo: Estudo prognóstico Limite: Animais / Humanos Idioma: Inglês Revista: Korean Circulation Journal Ano de publicação: 2008 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Capilares / Síncrotrons / Meios de Contraste / Embolia / Microvasos / Coração / Iodo / Isquemia Tipo de estudo: Estudo prognóstico Limite: Animais / Humanos Idioma: Inglês Revista: Korean Circulation Journal Ano de publicação: 2008 Tipo de documento: Artigo