Determination of curcumol and germacrone in Zedoary Turmeric Oil and Glucose Injections by RP-HPLC / 中成药
Article em Zh | WPRIM | ID: wpr-574207
Biblioteca responsável: WPRO
ABSTRACT
AIM: To establish a HPLC method for determination of curcumol and germacrone in Zedoary Turmeric Oil and Glucose Injections. METHODS: RP-HPLC was applied for quantitative analysis of curcumol and germacrone. Hypersil ODS2 column (250 mm? 4.6 mm, 5 ?m) and gradient elution was used. Mobile phase A was acetonitrile and mobile phase B was water. Phase A time-percentage composition was as follows:0-3 min,45%;3-30 min,45%→65%;30-38 min, 65%; 38-45 min, 65%→90%;45-55 min,90%→100%;55-65 min,100%. The flow rate was at 1.0 mL?min -1 . Diode array detector was set at 214 nm and column temperature was at 25 ?C. RESULTS: The calibration curves of curcumol and germacrone were linear in the range of 0.26 - 6.5 ?g(r= 0.999 9 ) and 0.112 5 - 2.812 5 ?g(r=1), The average recoveries of them were 102.1% and 98.8% (n=5), respectively. CONCLUSION: Curcumol and germacrone can be determined by the method, and this will improve the quality control of Zedoary Turmeric Oil and Glucose Injections.
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Traditional Patent Medicine Ano de publicação: 1992 Tipo de documento: Article