Determination of residuum from gardenia extract by macroporous adsorption resin / 中成药
Chinese Traditional Patent Medicine
;
(12)1992.
Artigo
em Chinês
| WPRIM
| ID: wpr-574756
ABSTRACT
AIM:
To establish the method of determining methylbenzene、dimethylbenzene、divinylbenzene、and phenylethene in gardenia extract.METHODS:
The GC system consisted of DB-INNOWax capillary chromatographic column,nitrogen as the carrier gas,and FID as the detector.RESULTS:
Methylbenzene was less than 890 mg/L,dimethylbenzene 2 170 mg/L,divinylbenzene and phenylethene 2000 mg/L,vespectively in gardenia extract. The average recoveries were within 96.8%~104.4%.The limits of detection were 0.125 mg/L-2.87 mg/L.CONCLUSION:
The method is sensitive,accurate and reproducible,and it can be used to control the quality of gardenia extract.