Effect of Two Air Disinfection Methods in Unremitting Operating Room:Comparison and Evaluation / 中华医院感染学杂志
Chinese Journal of Nosocomiology
; (24)2006.
Article
em Zh
| WPRIM
| ID: wpr-589475
Biblioteca responsável:
WPRO
ABSTRACT
OBJECTIVE To study air disinfection methods in unremitting operating room,we compared effect of using trioxide disinfector(used in operating room "A") with YKX/G100-type medical air disinfection and purification machine(used in operating room "B") in disinfecting air inside unremitting operating room.METHODS To observe the killing effect on air natural bacteria of the two methods,we used natural sedimentation monitoring the different stages sampling before and after sterilization and at the beginning stage of the unremitting operation.RESULTS Both the two methods could achieve the air natural bacteria eradication rate above 85%.The air bacteria colony number obviously upgraded after the beginning of unremitting operation in operating rooms "A";but in operating rooms "B",the number fell-off slowly.CONCLUSIONS The medical air disinfection and purification machine can shorten the interval of operations,it is the better approach of continuous air disinfection in solving the unremitting operating room with personnel existence.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Nosocomiology
Ano de publicação:
2006
Tipo de documento:
Article