Development of Multi-function Blooding Device for Blood Sucking Insects / 医疗卫生装备
Chinese Medical Equipment Journal ; (6)2003.
Artigo em Chinês | WPRIM | ID: wpr-592784
ABSTRACT
Objective To develop a blooding device for blood sucking insects. It's designed for researches, such as artificial breeding of indoor medium insects, evaluation of vermicides'effect, and artificial infection of pathogenic microorganisms. Methods This device was developed with AT89C51 MCU. Results The desired instrument could provide blood which could be adjusted from 30℃to 38℃. The error of temperature could be controlled within 0.5℃. Conclusion The instrument is easily-operated and stable. It can replace the artificial blood-breeding.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Medical Equipment Journal Ano de publicação: 2003 Tipo de documento: Artigo