The evaluation of 3D-CISS sequence in diagnosis of midbrain aqueduct obstruction / 实用放射学杂志
Journal of Practical Radiology
;
(12): 908-910,922, 2014.
Artigo
em Chinês
| WPRIM
| ID: wpr-599336
ABSTRACT
Objective To explore the value of three-dimensional constructive inference in steady state sequence (3D-CISS se-quence)in case of midbrain aqueduct obstruction.Methods 46 cases with midbrain aqueduct obstruction were scanned with FLASH T1 WI、TSE T2 WI and 3D-CISS sequence at 3.0T superconductive MR scanner.The original images of the 3D-CISS sequence were reconstructed.The images of three sequences showing midbrain aqueduct obstruction were observed and analyzed.Results The de-tection rate of the midbrain aqueduct obstruction was 13% 、71.7% and 100% in FLASH T1 WI、TSE T2 WI and 3D-CISS sequence, respectively.The difference between the three sequences were significant (P <0.01 67).Conclusion 3D-CISS sequence shows mid-brain aqueduct obstruction more accurately.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Tipo de estudo:
Estudo diagnóstico
Idioma:
Chinês
Revista:
Journal of Practical Radiology
Ano de publicação:
2014
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS