ABSTRACT
Objective To evaluate the feasibility and effectiveness of four closure techniques ,large incision with plastic distal at‐tachment and clip with suction ,1 .1 cm small incision with plastic distal attachment and clip with suction in natural orifice translu‐minal endoscopic surgery(NOTES) .Methods Forty‐one ex vivo porcine stomachs were involved in this research .According to the size of incision and different methods of incision closure ,all ex vivo porcine stomachs were divided into four groups .Group A in‐volved 8 ex vivo porcine stomachs ,their size of incision were 1 .2-2 .0 cm ,and their incisions were closured by a clip closure direct‐ly ;group B involved 10 ex vivo porcine stomachs ,their size of incision were 1 .2-2 .0 cm ,and their incisions were closed by plastic end attachment with suction and clip enclosure technique;group C involved 10 ex vivo porcine stomachs ,their size of incision were smaller than 1 .1 cm ,and their incisions were by a clip closure directly ;group D involved 13 ex vivo porcine stomachs ,their size of incision were smaller than 1 .1 cm ,and closured by plastic end attachment with suction and clip enclosure technique .Stomach leaks were evaluated by leaking studies after the procedure .Results In group A ,1 incision was closed successfully ,7 incisions were clo‐sured unsuccessfully ;in group B ,2 incisions were closed successfully ,8 incisions were closed unsuccessfully ;in group C ,2 incisions were closed successfully ,8 incisions were closured unsuccessfully ;in group D ,11 incisions were closed successfully ,2 incisions were Closured unsuccessfully .Fisher′s exact test showed that group D was significantly related to the success of incision closure .The were significant differences between group A and D ,group B and group D(P<0 .05) .Conclusion Small incision(smaller than 1 cm) and plastic end attachment with suction and clip enclosure technique are optimal in NOTES procedure in this ex vivo porcine stomachs study .

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chongqing Medicine Ano de publicação: 2014 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chongqing Medicine Ano de publicação: 2014 Tipo de documento: Artigo