Key optimization of light source parameters of lidar system for bioaerosol detection / 军事医学
Military Medical Sciences ; (12): 577-581,586, 2015.
Artigo em Chinês | WPRIM | ID: wpr-602234
ABSTRACT
Objective There are three categories of bioaerosol laser telemetry systems according to the light source configuration parametersnamely traditional lidar(light datection and ranging,laser radar), micro-pulse lidar and pseudo-random modulation(lidar).The system source parameters,which impact the degree of danger and detection sensitivity of the system, need to be optimized.Methods With reference to the USA laser product safety standards and by establishing the corresponding mathematical model of a lidar, the three categories of lidar source configuration were compared according to signal to noise ratio(SNR) and security before the repetition rate, pulse energy, divergence angle, distance and other dangerous impact factors were calculated.Results The results showed that to ensure eyesafety, the use of the pulse frequency should be set at 55 kHz for the highest SNR under the micro-pulse lidar excitation mode.Conclusion The eyesafety requirements impact the excitation of light source of a bioaerosol telemetry system.