Your browser doesn't support javascript.
loading
Evaluation the Value of Left Ventricular Rotation and Torsion in Pre-apical Hypertrophic Cardiomyopathy Diagnosis Using Two-dimensional Speckle Tracking Imaging / 中国医科大学学报
Journal of China Medical University ; (12): 704-708,713, 2015.
Artigo em Chinês | WPRIM | ID: wpr-602428
ABSTRACT
Objective To discuss the diagnostic value of two-dimensional speckle tracking imaging in the evaluation of left ventricular rotation and torsion in pre-apical hypertrophic cardiomyopathy(PAHCM)patients. Methods A total of 26 patients with PAHCM,26 patients with hyperten-sive left ventricular hypertrophy(HLVH)and 26 healthy volunteers were recruited for the study. Two-dimensional echocardiographs were performed carefully. Two-dimensional images were obtained from the left ventricular apical four-chamber section,two-chamber section and two short-axis sec-tions,including mitral valve and apical levels. The peak subendocardial rotation(endo-rot),epicardial rotation(epi-rot),transmural torsion(mural-tor)and bulk rotation(bulk-rot)of each short-axis section were measured and analyzed using QLAB 9.1 software. Results In the mitral level, there was no statistically significant difference in endo-rot,epi-rot,mural-tor and bulk-rot between the PAHCM group and normal control group (P>0.05). There was statistically significant difference in endo-rot,epi-rot,mural-tor and bulk-rot between the PAHCM group and HLVH group (all P0.05). There was statisti-cally significant difference in endo-rot,mural-tor and bulk-rot between each two groups(P<0.05). There was statistically significant difference in G-tor between each two groups(P<0.05). The receiver operating characteristic curve analysis showed that the accuracy of differential diagnosis of G-tor PAHCM was high(the area under the receiver operating characteristic curve is 0.89),the sensitivity was 73.08%,and the specificity was 92.31%. Conclusion Two-dimensional speckle tracking imaging could accurately and quantitatively measure the left ventricular rotation and tor-sion in PAHCM patients. The G-tor could accurately screen and identify between PAHCM and HLVH.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Chinês Revista: Journal of China Medical University Ano de publicação: 2015 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Chinês Revista: Journal of China Medical University Ano de publicação: 2015 Tipo de documento: Artigo