Application of a new device for blood collection by tail snipping in rats / 局解手术学杂志
Journal of Regional Anatomy and Operative Surgery
;
(6): 27-28,29, 2015.
Artigo
em Chinês
| WPRIM
| ID: wpr-604877
ABSTRACT
Objective To explore the effects of a new simple device for blood collection by tail snipping in rats so as to provide a safe, practical and repeatable method. Methods The rats were held by simple devices which made from plastic bottles and block and treated by some moderate ways for blood collection. Results The device was easy to be made and handled. 20 rats could have 6 times of blood collec-tion by this device in one day. There was no mouse death and no person injure during the experimental course. Conclusion This device is a safe and ideal equipment for blood collection by tail snipping in rats.