The technical investigation of 3.0T multi-modal quantitative MR imaging in rabbit liver / 实用放射学杂志
Journal of Practical Radiology
; (12): 644-647, 2017.
Article
em Zh
| WPRIM
| ID: wpr-608995
Biblioteca responsável:
WPRO
ABSTRACT
Objective To investigate the technical requirements for the 3.0T multi-modal quantitative MR imaging of the rabbit liver.Methods A total of 8 rabbits were scanned and T1 mapping,T2 mapping,MT and Gd EOB-DTPA dynamic enhancement images were acquired.For the dynamic enhanced scanning,injecting contrast medium was followed by saline flush with different combinations of injection flow rate (1.5 mL/s and 2 mL/s) and injection volume(6 mL and 8 mL).The quality of the images was assessed and analyzed statistically.Results The total scanning time was about 20-25 min.High-quality images were acquired by T1 mapping,T2 mapping and MT sequences.There was no significant difference in image quality among different groups in Gd-EOB-DTPA dynamic enhanced scanning(P>0.05).Two rabbits died when the combination of injection flow rate of 2 mL/s and injection volume of 8 mL was used.Conclusion 3.0 T multi-modal quantitative MR scanning of rabbit liver can be achieved successfully if scanning parameters are properly chosen.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Journal of Practical Radiology
Ano de publicação:
2017
Tipo de documento:
Article