Your browser doesn't support javascript.
loading
Determination of Nipagin Esters and Metronidazole Illegally Added to Chitosan Medical Devices / 中国药师
China Pharmacist ; (12): 924-927, 2017.
Artigo em Chinês | WPRIM | ID: wpr-610156
ABSTRACT

Objective:

To determine bacteriostatic drugs nipagin esters and metronidazole illegally added to chitosan medical devices.

Methods:

An HPLC method was used with a ZORBAX Eclipse XDB-C18(250 mm×4.6 mm, 5 μm)column.The mobile phase was water and acetonitrile(65∶35).The flow rate was 1.0 ml·min-1.The detection wavelength was 254 nm.The column temperature was 35℃ and the injection volume was 10 μl.

Results:

Nipagin esters were detected out in chitosan suppositories and gel.Metronidazole was detected out in chitosan lotion.

Conclusion:

The method is simple and fast, which has guiding significance for further comprehensive studies of bacteriostatic drugs illegally added to chitosan medical devices.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Pharmacist Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS