Your browser doesn't support javascript.
loading
Robotic mitral valve replacement: A single center, medium-long term follow-up of 43 cases / 解放军医学杂志
Medical Journal of Chinese People's Liberation Army ; (12): 549-552, 2017.
Artigo em Chinês | WPRIM | ID: wpr-612352
ABSTRACT
Objective To summarize the surgical experience gained from robotic mitral valve replacement (MVR), and demonstrate the long-term clinical follow-up results. Methods From Jan. 2007 to Jan. 2015, more than 700 patients underwent various types of robotic cardiac surgery in the Department the authors served in, and of them 43 patients underwent robotic MVR with da Vinci Surgical System (Intuitive Surgical, USA). Among the 43 patients, the average age was 47±11 years (ranged 19-65 years), and sex ratio (female to male) was 0.81. Six patients were with heart function of NYHA class Ⅰ, 30 patients were of NYHA class Ⅱ and 7 patients were of NYHA class Ⅲ. The left ventricular ejection fraction (LVEF) were 54%-78% (64.0%±7.1%), and 20 patients had atrial fibrillation on admission, and 35 patients were with rheumatic mitral stenosis (MS). Atrial septal defect (0.7cm in size) co-existed in 1 case and 1 patient had mild aortic regurgitation. Mechanical or bioprosthetic mitral valve was replaced via left atriotomy by using da Vinci robotic surgical system after cardiopulmonary bypass (CPB) set-up. Radiopaque titan clips was employed by Cor-Knot knot-tying device (LSI Solutions, Inc, Victor, NY) to anchor the prosthetic valve. Trans-esophageal echocardiography (TEE) was performed before and after surgery. The operative data were collected and patients were followed up at outpatient clinic regularly up to 6 years. Results All cases were performed successfully with the same surgery. No conversion to median sternotomy or operative mortality occurred. The average operation time was 292±62 minutes (ranged 140-450 minutes) with CPB time of 124±26 minutes and aortic occlusion time of 88±21 minutes. The postoperative mechanical ventilation support time was continued for 15±6 hours, and the average staying length in critical care unit was 4±1 days. No myocardial infarction, ventricular tachycardia or excessive bleeding was complicated. All patients were successfully followed up for a median of 3.5 years (ranged 1 month to 6 years). In the follow-up period, no incidence of death, stroke, re-operation due to prosthetic endocarditis or prosthetic failure was reported. However, 39.5% (n=17) patients still had atrial fibrillation after surgery. Conclusion Robotic MVR is a safe and effective procedure with excellent long term surgical outcome.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo prognóstico Idioma: Chinês Revista: Medical Journal of Chinese People's Liberation Army Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo prognóstico Idioma: Chinês Revista: Medical Journal of Chinese People's Liberation Army Ano de publicação: 2017 Tipo de documento: Artigo